CWDM Mux/DeMux

MUX.jpg

The 10Gtek's Mux/Demux supports up to 8 channels on a module, along with extra customized ports. Other than the typical OADM, 10Gtek's OADM has both of the function of Mux/Demux and OADM.

 

Users can either make the customized ports as monitor ports, pass pork or additional channel port. As to the additional channel, 1310 nm and 1550 nm are available for choosing.

 

With the height of 1U, 10Gtek's modules are friendly with all the cabinets in the data center or the office. What's more, the screws on both sides of the patch panel can fasten the module onto the 10Gtek's standard chassis which can also hold the MPO TAPs and LC TAPs provided by 10Gtek.

 

1.jpg

A. Common port:
      ● LC, SC, ST and FC connectors available.

B. Standard port 1310nm:
      ● Allows a legacy 1310nm signal to pass. That is to say, it can carry LR optics, LX optics etc.
      ● LC, SC, ST and FC connectors available.

C. Standard port 1550nm:
       ● Allows a legacy 1550nm signal to pass. That is to say, it can carry ER optics, ZR optics, LX optics, ZX optics etc.
       ● LC, SC, ST and FC connectors available.

D. Mux/Demux port for specific wavelengths:
       ● LC, SC, ST and FC connectors available.
       ● Compliant with the ITU G.657A1 standard as default.

E. Express port:
       ● Enables the cascading of two CWDM MUX/DEMUX modules, doubling the channel capacity on the common fiber link.
       ● Channel Isolation is 15dB as default, 16dB ~40dB available on request.
       ● LC, SC, ST and FC connectors available.

F. Monitor port:
       ● Connects measurement/monitoring equipment, such as power meters or network analyzers, to the module outputs.
       ● When finished monitoring, disconnect the instruments and the network is left undisturbed.
       ● LC, SC, ST and FC connectors available.
       ● Tap percentage is 5% as default, 1%, 2%, 3%, or 10% available on request.



NOTE:
● Actual layout depends on the chosen connector type as well as other factors. However, the principal scheme stays the same
● We provide optional port configurations such as: Express Port, Monitor Port, 1310nm passband port and 1550nm port for these multiplexers according to customer choice, need more details, please contact at info@FiberOnSale.com
● When using with 1310nm legacy SDH/SONET, CWDM wavelengths 1270, 1290, 1310, 1330 and 1350nm should not be used.
● When using with 1550nm legacy SDN/SONET, CWDM wavelengths 1510, 1530, 1550, 1570 and 1590nm should not be used.

Item Details


● 2 channels CWDM mux and demux in one 1U Rack
● Com port is duplex
● 1U 19 inch Rack Mount Housing
● It is equipped with configuration ports like Monitor, Express port according to customer choice (see options)
● Front panel is equipped with adapters according to customer choice (see options)
● Passive, no electric power required. (MTBF ca. 500 years)
● Low insertion loss
● Simple to install, requires no configuration or maintenance
● ISO 9001 manufacturing facility

 

Parameters Unit CWDM Module
Wavelength Range nm 1260 ~ 1620
Channel Center Wavelength nm 1270 / 1290 / … / 1610 or 1271 / 1291 / … /1611
Channel Spacing nm 20
Channel Passband nm λc ± 7.5
Channel No. λ 2 4 8 16 18
Insertion Loss dB ≤0.8 ≤1.5 ≤2.5 ≤5.2 ≤6.4
Adjacent Channel Isolation dB ≥ 30
Non-adjacent Channel Isolation dB ≥ 40
Wavelength thermal stability nm/℃ ≤ 0.003
Insertion loss thermal stability dB/℃ ≤ 0.005 ≤ 0.007 ≤ 0.008
PDL dB ≤ 0.1 ≤0.15 ≤ 0.15 ≤ 0.20 ≤ 0.25
Polarization mode dispersion ps ≤ 0.1 ≤ 0.15
Directivity dB ≥ 50
Return loss dB ≥ 45
Optical Power mW ≤ 500
Operating Temperature -10 ~ +70
Storage Temperature -40 ~ +85
Relative Humidity % 5 ~ 95
Dimension   ABS Box or LGX Box or 1U(2U) Rackmount
Note:
1. Customization is available.
2. We can make low insertion loss solution as well. For more information, please feel free to contact at info@fiberonsale.com.
3. Specified without connector, and add an additional 0.2dB loss per connector.

 

 

CWDM Mux

  • 2 channels CWDM mux and demux in one 1U Rack
  • Com port is duplex
  • 1U 19 inch Rack Mount Housing
  • It is equipped with configuration ports like Monitor, Express port according to customer choice (see options)
  • Front panel is equipped with adapters according to customer choice (see options)
  • Passive, no electric power required. (MTBF ca. 500 years)
  • Low insertion loss
  • Simple to install, requires no configuration or maintenance
  • ISO 9001 manufacturing facility

  

P/N Description CWDM Mux/Demux Fiber Channel Wavelength Monitor 1310nm window 1550nm window insertion loss Connector
CM1-18AM CWDM Mux/Demux 18 Channel, 1270~1610nm, w/ Monitor, <4.25dB, LC CWDM Mux/Demux Dual Fiber 18 Channel 1270~1610nm w/ Monitor Option Option <4.25dB LC
CM1-16AM CWDM Mux/Demux 16 Channel, 1270~1350nm,1410~1610nm, w/ Monitor, <3.75dB, LC CWDM Mux/Demux Dual Fiber 16 Channel 1270~1350nm, 1410~1610nm w/ Monitor Option Option <3.75dB LC
CM1-16xM CWDM Mux/Demux 16 Channel, Customized, w/ Monitor, <3.75dB, LC CWDM Mux/Demux Dual Fiber 16 Channel Customized w/ Monitor Option Option <3.75dB LC
CM1-8AM CWDM Mux/Demux 8 Channel, 1470~1610nm, w/ Monitor, <2.75dB, LC CWDM Mux/Demux Dual Fiber 8 Channel 1470~1610nm w/ Monitor Option Option <2.75dB LC
CM1-8BM CWDM Mux/Demux 8 Channel, 1270~1430nm, w/ Monitor, <2.75dB, LC CWDM Mux/Demux Dual Fiber 8 Channel 1270~1430nm w/ Monitor Option Option <2.75dB LC
CM1-8CM CWDM Mux/Demux 8 Channel, 1270~1350nm,1410~1450nm, w/ Monitor, <2.75dB, LC CWDM Mux/Demux Dual Fiber 8 Channel 1270~1350nm, 1410~1450nm w/ Monitor Option Option <2.75dB LC
CM1-8DM CWDM Mux/Demux 8 Channel, 1270~1410nm, w/ Monitor, <2.75dB, LC CWDM Mux/Demux Dual Fiber 8 Channel 1270~1410nm w/ Monitor Option Option <2.75dB LC
CM1-8xM CWDM Mux/Demux 8 Channel, Customized, w/ Monitor, <2.75dB, LC CWDM Mux/Demux Dual Fiber 8 Channel Customized w/ Monitor Option Option <2.75dB LC
CM1-4AM CWDM Mux/Demux 4 Channel, 1470~1530nm, w/ Monitor, <1.75dB, LC CWDM Mux/Demux Dual Fiber 4 Channel 1470~1530nm w/ Monitor Option Option <1.75dB LC
CM1-4BM CWDM Mux/Demux 4 Channel, 1510~1570nm, w/ Monitor, <1.75dB, LC CWDM Mux/Demux Dual Fiber 4 Channel 1510~1570nm w/ Monitor Option Option <1.75dB LC
CM1-4CM CWDM Mux/Demux 4 Channel, 1550~1610nm, w/ Monitor, <1.75dB, LC CWDM Mux/Demux Dual Fiber 4 Channel 1550~1610nm w/ Monitor Option Option <1.75dB LC
CM1-4DM CWDM Mux/Demux 4 Channel, 1270~1330nm, w/ Monitor, <1.75dB, LC CWDM Mux/Demux Dual Fiber 4 Channel 1270~1330nm w/ Monitor Option Option <1.75dB LC
CM1-4EM CWDM Mux/Demux 4 Channel, 1290~1350nm, w/ Monitor, <1.75dB, LC CWDM Mux/Demux Dual Fiber 4 Channel 1290~1350nm w/ Monitor Option Option <1.75dB LC
CM1-4xM CWDM Mux/Demux 4 Channel, Customized, w/ Monitor, <1.75dB, LC CWDM Mux/Demux Dual Fiber 4 Channel Customized w/ Monitor Option Option <1.75dB LC
CM1-2xM CWDM Mux/Demux 2 Channel, Customized, w/ Monitor, <1.25dB, LC CWDM Mux/Demux Dual Fiber 2 Channel Customized w/ Monitor Option Option <1.25dB LC